Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 29, 2016, 07:00 AM
  • 03 0144_03 0143_20160830_011306.mp4

Date
08/29/2016
W/O
579967
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00363
PipeID
P04760
Time
12:00 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3693
Sewer Name
03 LAKEWOOD TRUNK
City
LAKEWOOD, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Routine Assessment
Project
WO_579967_TV03005_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
03 0144
Downstream MH
03 0143
Dir. of Survey
Downstream
Length Surveyed
357.5 ft.
Total Length
357.5 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 03 0144 to 03 0143
MH: 03 0144MH: 03 0143downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 03 01440 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE0 ft. MWL - Water Level, 20 %of cross sectional area3.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start65.1 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES141.8 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES167.8 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"273.6 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"355.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish357.5 ft. AMH - Downstream Manhole, Survey Ends - 03 0143

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    65.1 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    141.8 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
167.8TBA
273.6TBA
355.3DAGS
3.9DAGS
141.8CM
0MWM
357.5AMH03 0143
65.1CM
0AMH03 0144
0MGOCONNECTION AT THE MH 9 O'CLOCK ACTIVE
0MWL

Properties (6)

additional_info
SC306023
custom_field_two
4
customer
LACSD
datetime
2016-08-29T00:00:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false