Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 30, 2016, 10:35 AM
  • 03 0141A_03 0141_20160830_044247.mp4

Date
08/30/2016
W/O
579967
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00363
PipeID
P05123
Time
3:35 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3693
Sewer Name
03 LAKEWOOD TRUNK
City
LAKEWOOD, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Routine Assessment
Project
WO_579967_TV03005_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
03 0141
Downstream MH
03 0141A
Dir. of Survey
Upstream
Length Surveyed
181.8 ft.
Total Length
181.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 03 0141 to 03 0141A
MH: 03 0141MH: 03 0141Aupstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 03 141A0.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish179.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start181.8 ft. MWM - Water Mark, 35 %of cross sectional area181.8 ft. AMH - Downstream Manhole, Survey Begins - 03 0141181.8 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
181.5DAGS
181.8MGOCONNECTION AT THE MH 9 O'CLOCK ACTIVE
181.8AMH03 141A
0MWM
0AMH03 0141
2DAGS
0MWL

Properties (6)

additional_info
SC306023
custom_field_two
4
customer
LACSD
datetime
2016-08-30T03:35:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false