Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 12, 2017, 05:03 PM
  • 30 0122_30 0121_6122017_100420.mp4

  • 30 0122_30 0121_6122017_103200.mp4

Date
06/12/2017
W/O
0635597
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00878
PipeID
P17826
Time
10:03 AM
Certificate
415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7432
Sewer Name
30 SOUTH BAY CITIES MAIN TRUNK
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
06
Purpose
Routine Assessment
Project
20170612DF_SOUTH_BAY_CITIES_MAIN_TR
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
30 0122
Downstream MH
30 0121
Dir. of Survey
Downstream
Length Surveyed
427.1 ft.
Total Length
427.1 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 30 0122 to 30 0121
MH: 30 0122MH: 30 0121downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 10l03 AM0.1 ft. MWL - Water Level, 30 %of cross sectional area2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 55% MAG COAT2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start49.9 ft. MGP - General Photograph - PEELING/FLAKING52.5 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4" - Open108.8 ft. MGP - General Photograph - 15-20% MAG COAT205.3 ft. MGP - General Photograph263.6 ft. MGP - General Photograph - PEELING/FLAKING331.6 ft. MGP - General Photograph425.7 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 55% MAG COAT425.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish427.1 ft. AMH - Downstream Manhole, Survey Ends - 10:43 AM

Observation photos (6)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph - PEELING/FLAKING

    49.9 ft. - General Photograph - PEELING/FLAKING

  • General Photograph - 15-20% MAG COAT

    108.8 ft. - General Photograph - 15-20% MAG COAT

  • General Photograph

    205.3 ft. - General Photograph

  • General Photograph - PEELING/FLAKING

    263.6 ft. - General Photograph - PEELING/FLAKING

  • General Photograph

    331.6 ft. - General Photograph

Observations (14)

DistanceCodeObservation
0.1MWL
263.6MGPPEELING/FLAKING
52.5TFOpen
331.6MGP
425.7SZ55% MAG COAT
205.3MGP
49.9MGPPEELING/FLAKING
2SZ55% MAG COAT
2SSS
0MWM
427.1AMH10:43 AM
0AMH10l03 AM
425.8SSS
108.8MGP15-20% MAG COAT

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2017-06-12T10:03:30-07:00
documentation
FRANKLIN, IGNACIO, BRAR
is_lateral_inspection
false