Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 9, 2017, 09:18 AM
  • 03 0433_03 0432_692017_051613.mp4

Date
06/09/2017
W/O
0630072
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00406
PipeID
P04981
Time
2:18 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0557
Sewer Name
03 WATER STREET TRUNK
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
22
Purpose
Capital Improvement Program Assesment
Project
20170609MDM_WATER_STREET_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Upstream MH
03 0433
Downstream MH
03 0432
Dir. of Survey
Downstream
Length Surveyed
173.7 ft.
Total Length
173.7 ft.
Structural Index
4
Structural Quick
5242
Structural Rating
23
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
28
Pipe schematic from manhole 03 0433 to 03 0432
MH: 03 0433MH: 03 0432downstream0 ft. AMH - Upstream Manhole, Survey Begins - 4:45AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - SLUDGE2 ft. MGP - General Photograph - REBAR2 ft. SRC - Surface Reinforcement Corroded, from 12 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM& LONG REBAR6.5 ft. SRC - Surface Reinforcement Corroded, from 12 to 04 o'clock, within 8 inches of joint: YES, Finish - CIRCUM & LONG REBAR8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE8 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC8 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - SLUDGE25.6 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - SLUDGE144.4 ft. SRV - Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - CIRCUM & LONG REBAR173.5 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish - SLUDGE173.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish173.5 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish173.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish173.5 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active173.7 ft. AMH - Downstream Manhole, Survey Ends - 5:05AM

Observation photos (6)

  • General Photograph - REBAR

    2 ft. - General Photograph - REBAR

  • Surface Reinforcement Corroded, from 12 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM& LONG REBAR

    2 ft. - Surface Reinforcement Corroded, from 12 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM& LONG REBAR

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

    8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

  • Deposits Settled Other,  20 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start - SLUDGE

    25.6 ft. - Deposits Settled Other, 20 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - SLUDGE

  • Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - CIRCUM & LONG REBAR

    144.4 ft. - Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - CIRCUM & LONG REBAR

Observations (20)

DistanceCodeObservation
0AMH4:45AM
144.4SRVCIRCUM & LONG REBAR
8SSSBLISTERING PEELING CONCRETE
173.5DSZSLUDGE
6.5SRCCIRCUM & LONG REBAR
173.5SAP
8SAMSEVERE AGG
173.7AMH5:05AM
173.5SAM
8SAPSEVERE AGG SPORATIC
173.5SSS
2SAMSEVERE AGG
0MWM
173.5MGOConn. @ Mh, 3 O' Clock. Active
2DSZSLUDGE
25.6DSZSLUDGE
8DSZSLUDGE
0MWL
2MGPREBAR
2SRCCIRCUM& LONG REBAR

Properties (6)

custom_field_three
LONG & CIRCUM REBAR
custom_field_two
3
customer
LACSD
datetime
2017-06-09T02:18:58-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false