Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 16, 2016, 07:22 PM
  • H 0885_H 0884_20020101_015008.mp4

Date
05/16/2016
W/O
557604
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00939
PipeID
P20442
Time
12:22 PM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3456
Sewer Name
H JOINT OUTFALL H - UNIT 8A RELIEF
City
LA PUENTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
WO_557604_TV15074_MAY2016
Sewer Type
GRAVITY
Material
RCP-PTL
Shape
Circular
Height
48 in.
Upstream MH
H 0885
Downstream MH
H 0884
Dir. of Survey
Downstream
Length Surveyed
611 ft.
Total Length
611 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2W00
O&M Rating
242
Overall Index
2
Overall Quick
Overall Rating
242
Pipe schematic from manhole H 0885 to H 0884
MH: H 0885MH: H 0884downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 08850 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area1.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start608.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish611 ft. AMH - Downstream Manhole, Survey Ends - H 0884

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    1.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0AMHH 0885
1.7DAGS
608.8DAGS
0MWL
0MWM
611AMHH 0884

Properties (7)

additional_info
SC305477
custom_field_two
4
customer
LACSD
datetime
2016-05-16T12:22:17-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
19920123