Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 20, 2016, 07:01 AM
  • H 0845_H 0844_20160520_012351.mp4

Date
05/20/2016
W/O
557604
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00939
PipeID
P20405
Time
12:01 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3460
Sewer Name
H JOINT OUTFALL H - UNIT 8A RELIEF
City
LA PUENTE
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
30
Purpose
Routine Assessment
Project
WO_557604_TV15074_MAY2016
Sewer Type
GRAVITY
Material
RCP-PTL
Shape
Circular
Height
54 in.
Upstream MH
H 0845
Downstream MH
H 0844
Dir. of Survey
Downstream
Length Surveyed
195.5 ft.
Total Length
195.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2G00
O&M Rating
76
Overall Index
2
Overall Quick
Overall Rating
76
Pipe schematic from manhole H 0845 to H 0844
MH: H 0845MH: H 0844downstream0 ft. MGO - General Observation - CONNECTION AT MH ACTIVE 9 OCLOCK0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 08451.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start191.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish195.5 ft. AMH - Downstream Manhole, Survey Ends - H 0844

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    1.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MGOCONNECTION AT MH ACTIVE 9 OCLOCK
195.5AMHH 0844
0MWM
0MWL
191.1DAGS
1.8DAGS
0AMHH 0845

Properties (7)

additional_info
SC305482
custom_field_two
4
customer
LACSD
datetime
2016-05-20T00:01:39-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
19921028