Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 15, 2017, 08:07 PM
  • J 0032A_J 0032_15112017_120913.mpg

Date
11/15/2017
W/O
668772
Weather
Dry
Operator/Surveyor
E RUIZ
Sewer ID
Z00061
PipeID
P11609
Time
12:07 PM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5130
Sewer Name
J JOINT OUTFALL J - UNIT 2B
City
LOMITA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
36
Purpose
Routine Assessment
Project
WO_668772_TV05231_NOV2017
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Upstream MH
J 0032A
Downstream MH
J 0032
Dir. of Survey
Downstream
Length Surveyed
11 ft.
Total Length
11 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole J 0032A to J 0032
MH: J 0032AMH: J 0032downstream0 ft. AMH - Upstream Manhole, Survey Begins - J 0032A0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area3 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - THROUGHOUT THE REACH10 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES11 ft. MSA - Survey Abandoned - VIEW OF THE D/S SIPHON FROM THE U/S MH

Observation photos (2)

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - THROUGHOUT THE REACH

    3 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES - THROUGHOUT THE REACH

  • Survey Abandoned - VIEW OF THE D/S SIPHON FROM THE U/S MH

    11 ft. - Survey Abandoned - VIEW OF THE D/S SIPHON FROM THE U/S MH

Observations (6)

DistanceCodeObservation
0AMHJ 0032A
10SAV
3SRVTHROUGHOUT THE REACH
0MWL
0MWM
11MSAVIEW OF THE D/S SIPHON FROM THE U/S MH

Properties (6)

additional_info
SC348338
custom_field_two
2
customer
LACSD
datetime
2017-11-15T12:07:40-08:00
documentation
PROPIPE
is_lateral_inspection
false