Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 9, 2017, 06:27 AM
  • H 1479_H 1478 _081117_224749.mpg

Date
11/08/2017
W/O
668649
Weather
Dry
Operator/Surveyor
ERUIZ
Sewer ID
Z01206
PipeID
P16439
Time
10:27 PM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5133
Sewer Name
H JOINT OUTFALL H - UNIT 8M RELIEF
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
WO_668649_TV22094_NOV2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
H 1479
Downstream MH
H 1478
Dir. of Survey
Downstream
Length Surveyed
762.2 ft.
Total Length
762.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole H 1479 to H 1478
MH: H 1479MH: H 1478downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 14790 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area8.7 ft. MGO - General Observation - MAGNEZIUM H.O COATING start8.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start144.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"225.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"318.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"400.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"535.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"615.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"648.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"684.5 ft. LL - Alignment Left, 20 %758.4 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish762.2 ft. AMH - Downstream Manhole, Survey Ends - H 1478

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    8.7 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
318.4TFA
0AMHH 1479
8.7MGOMAGNEZIUM H.O COATING start
225.3TFA
8.7SAP
400.1TFA
615.6TFA
758.4SAP
0MWM
684.5LL
648.2TFA
0MWL
535.9TFA
762.2AMHH 1478
144.2TFA

Properties (7)

additional_info
SC348341
custom_field_two
3
customer
LACSD
datetime
2017-11-08T22:27:29-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
27198