Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 3, 2017, 10:47 AM
  • 05 1143_05 1142 _11032017_034817.mp4

Date
11/03/2017
W/O
668623
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00436
PipeID
P06382
Time
3:47 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5208
Sewer Name
05 EAST ROSECRANS AVENUE TRUNK, SECTION 1
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
WO_668623_TV05022_NOV2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 1143
Downstream MH
05 1142
Dir. of Survey
Downstream
Length Surveyed
326.9 ft.
Total Length
326.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2L00
O&M Rating
130
Overall Index
2
Overall Quick
Overall Rating
130
Pipe schematic from manhole 05 1143 to 05 1142
MH: 05 1143MH: 05 1142downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 11430 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - HANGING STEP ON THE SOFFIT0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start68.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"173.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"241.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"282 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"324.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish324.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE326.9 ft. AMH - Downstream Manhole, Survey Ends - 05 1142

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0AMH05 1143
68.5TFC
173.7TFC
0MGOCOCKROACHES IN MANHOLE
241.8TFA
326.9AMH05 1142
0MWL
2DAGS
324.9DAGS
324.9MGOCOCKROACHES IN MANHOLE
0MGOHANGING STEP ON THE SOFFIT
0MWM
282TFC

Properties (6)

additional_info
SC346078
custom_field_two
4
customer
LACSD
datetime
2017-11-03T03:47:41-07:00
documentation
PRO PIPE
is_lateral_inspection
false