- Date
- 11/29/2016
- W/O
- 602586
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00093
- PipeID
- P08970
- Time
- 3:45 AM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3889
- Sewer Name
- B JOINT OUTFALL B - UNIT 5C
- City
- PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- WO_602586_TV16079_NOV2016
- Sewer Type
- Siphon
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- B 0456
- Downstream MH
- B 0457
- Dir. of Survey
- Upstream
- Length Surveyed
- 2.1 ft.
- Total Length
- 2.1 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 3
- O&M Quick
- 3100
- O&M Rating
- 3
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole B 0456 to B 0457 Observation photos (2)

0 ft. - Deposits Attached Ragging, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO

2.1 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES