Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 2, 2018, 06:30 AM
  • 29 0406_29 0405 _01102018_233017.mp4

Date
10/01/2018
W/O
729465
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01090
PipeID
P24443
Time
11:30 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6120
Sewer Name
29 ALAMITOS PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_729465_TV29104_OCT2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0405
Downstream MH
29 0406
Dir. of Survey
Upstream
Length Surveyed
268.4 ft.
Total Length
268.4 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
159
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
161
Pipe schematic from manhole 29 0405 to 29 0406
MH: 29 0405MH: 29 0406upstream0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. ACOM - Cleanout Mainline, Survey Ends - 29 04060.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"1.9 ft. MGO - General Observation - C/O7.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"25.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"27.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"64.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"72 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"92.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"105.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"136 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"146.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"177.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"225.4 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"231 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"262.5 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - FRACTURE'S265.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start268.4 ft. AMH - Downstream Manhole, Survey Begins - 29 0405268.4 ft. MWL - Water Level, 5 %of cross sectional area268.4 ft. MWM - Water Mark, 5 %of cross sectional area

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - FRACTURE'S

    5.9 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - FRACTURE'S

Observations (22)

DistanceCodeObservation
37.4TFA
196.4TF
122.1TF
91TF
5.9TFDFRACTURE'S
0AMH29 0405
163.2TF
2.9CM
204.1TF
241.3TF
132.4TF
266.5MGOC/O
268.4CM
268.4ACOM29 0406
43TF
93.7TF
176.1TF
268.3TF
0MWL
0MWM
260.6TFC
242.8TF

Properties (4)

additional_info
SC364840
custom_field_two
3
customer
LACSD
datetime