Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 8, 2018, 10:12 AM
  • 08 047708 0645 District 08_112118135154.mpg

Date
10/08/2018
W/O
729415
Weather
Dry
Operator/Surveyor
B. FUGATE
Sewer ID
Z00025
PipeID
P20118
Time
3:12 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6132
Sewer Name
08 216TH STREET RELOCATION TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_729415_TV08140_OCT2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
08 0477
Downstream MH
08 0645
Dir. of Survey
Downstream
Length Surveyed
21.9 ft.
Total Length
21.9 ft.
Structural Index
4
Structural Quick
5334
Structural Rating
27
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
27
Pipe schematic from manhole 08 0477 to 08 0645
MH: 08 0477MH: 08 0645downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 04770 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area3.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.5 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES9.7 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO, Start21.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish21.9 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish21.9 ft. AMH - Downstream Manhole, Survey Ends - 08 0645

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    3.5 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    9.7 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

Observations (9)

DistanceCodeObservation
0AMH08 0477
9.7SRC
0MWL
21.9SAP
21.9SRC
0MWM
3.5SRV
21.9AMH08 0645
3.2SAP

Properties (4)

additional_info
SC365202
custom_field_two
2
customer
LACSD
datetime
2018-10-08T03:12:00-07:00