Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 3, 2018, 09:16 AM
  • Section#1_A 0020_B 0929__1232018__I0081.mp4

Date
12/03/2018
W/O
07343334
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00333
PipeID
P20071
Time
1:16 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0081
Sewer Name
A JOINT OUTFALL A - UNIT 3B
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
14
Purpose
Capital Improvement Program Assesment
Project
20181203MDM_JOINT_OUTFALL_A_UNIT_3B
Material
RCP-CTL
Shape
Square
Height
114 in.
Width
114 in.
Upstream MH
A 0020
Downstream MH
B 0929
Dir. of Survey
Downstream
Length Surveyed
637.9 ft.
Total Length
637.9 ft.
Structural Index
4
Structural Quick
5A4Y
Structural Rating
580
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
585
Pipe schematic from manhole A 0020 to B 0929
MH: A 0020MH: B 0929downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM0 ft. MGO - General Observation - MH CONN 3:00 OPEN-FALLING LINER0 ft. MWL - Water Level, 45 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SREAS OF MISSING TILES2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR2 ft. MGO - General Observation - MISSING TILES 95% START 10:00 TO 2:002 ft. MGO - General Observation - MAG COAT 60% START23.5 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG & CIRCUM REBAR23.5 ft. MGO - General Observation - MISSING TILES 10% START33.3 ft. MGO - General Observation - MISSING TILES 30% UNDER MAG COAT55.5 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG UNDER MAG COAT65.7 ft. MGO - General Observation - MISSING TILES 80% START 9:00 TO 3:00113.4 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG149.1 ft. MGO - General Observation - MISSING TILES 70% START224.1 ft. MGO - General Observation - 80% MISSING TILES START 9:00 TO 3:00249.8 ft. MGO - General Observation - 95% TILES IN PLACE SECTION322.3 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG568 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT POSSIBLE584.7 ft. MGO - General Observation - TILES IN PLACE ONE AREA608.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR619.3 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR637.4 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - CIRCUM REBAR637.4 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG637.9 ft. AMH - Downstream Manhole, Survey Ends - 3:15AM

Observation photos (18)

  • General Observation - MH CONN 3:00 OPEN-FALLING LINER

    0 ft. - General Observation - MH CONN 3:00 OPEN-FALLING LINER

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SREAS OF MISSING TILES

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SREAS OF MISSING TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

    2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

  • General Observation - MISSING TILES 95% START 10:00 TO 2:00

    2 ft. - General Observation - MISSING TILES 95% START 10:00 TO 2:00

  • General Observation - MAG COAT 60% START

    2 ft. - General Observation - MAG COAT 60% START

  • General Observation - MISSING TILES 10% START

    23.5 ft. - General Observation - MISSING TILES 10% START

  • General Observation - MISSING TILES 30% UNDER MAG COAT

    33.3 ft. - General Observation - MISSING TILES 30% UNDER MAG COAT

  • Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG UNDER MAG COAT

    55.5 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG UNDER MAG COAT

  • General Observation - MISSING TILES 80% START 9:00 TO 3:00

    65.7 ft. - General Observation - MISSING TILES 80% START 9:00 TO 3:00

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

    113.4 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • General Observation - MISSING TILES 70% START

    149.1 ft. - General Observation - MISSING TILES 70% START

  • General Observation - 80% MISSING TILES START 9:00 TO 3:00

    224.1 ft. - General Observation - 80% MISSING TILES START 9:00 TO 3:00

  • General Observation - 95% TILES IN PLACE SECTION

    249.8 ft. - General Observation - 95% TILES IN PLACE SECTION

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    322.3 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT POSSIBLE

    568 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT POSSIBLE

  • General Observation - TILES IN PLACE ONE AREA

    584.7 ft. - General Observation - TILES IN PLACE ONE AREA

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR

    608.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    619.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

Observations (25)

DistanceCodeObservation
584.7MGOTILES IN PLACE ONE AREA
2SAMSEVERE AGG SREAS OF MISSING TILES
568SRCCIRCUM REBAR UNDER MAG COAT POSSIBLE
0MWM
2SRCLONG & CIRCUM REBAR
608.1SRCCIRCUM REBAR
619.3SRCCIRCUM REBAR
0AMH1:55AM
2MGOMISSING TILES 95% START 10:00 TO 2:00
224.1MGO80% MISSING TILES START 9:00 TO 3:00
637.9AMH3:15AM
0MGOMH CONN 3:00 OPEN-FALLING LINER
65.7MGOMISSING TILES 80% START 9:00 TO 3:00
0MWL
249.8MGO95% TILES IN PLACE SECTION
55.5SAMSEVERE AGG UNDER MAG COAT
2MGOMAG COAT 60% START
637.4SRCCIRCUM REBAR
33.3MGOMISSING TILES 30% UNDER MAG COAT
637.4SAMSEVERE AGG
23.5SRCLONG & CIRCUM REBAR
113.4SAMSEVERE AGG
322.3SAMSEVERE AGG
149.1MGOMISSING TILES 70% START
23.5MGOMISSING TILES 10% START

Properties (6)

custom_field_three
CORRODED LONG & CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2018-12-03T01:16:18-08:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false