Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 30, 2018, 09:54 AM
  • 16 0697_16 0696_11302018_030104.mp4

Date
11/30/2018
W/O
0742114
Weather
Light Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00665
PipeID
P22017
Time
1:54 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1066
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
21
Purpose
Routine Assessment
Project
20181130MDM_SAN_MARINO_OUTFALL_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
16 0697
Downstream MH
16 0696
Dir. of Survey
Downstream
Length Surveyed
108.3 ft.
Total Length
108.3 ft.
Structural Index
1
Structural Quick
1100
Structural Rating
1
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
3
Pipe schematic from manhole 16 0697 to 16 0696
MH: 16 0697MH: 16 0696downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:55AM5.6 ft. JOM - Joint Offset Medium - SEALED30 ft. MGO - General Observation - 24" VCP60.1 ft. DSGV - Deposits Settled Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES70.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open73.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active108.3 ft. AMH - Downstream Manhole, Survey Ends - 3:10AM

Observation photos (2)

  • Joint Offset Medium - SEALED

    5.6 ft. - Joint Offset Medium - SEALED

  • General Observation - 24" VCP

    30 ft. - General Observation - 24" VCP

Observations (9)

DistanceCodeObservation
0MWL
30MGO24" VCP
0MWM
70.4TFOpen
108.3AMH3:10AM
5.6JOMSEALED
60.1DSGV
73.5TFActive
0AMH2:55AM

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2018-11-30T01:54:34-08:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false