Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 30, 2018, 11:19 AM
  • 16 0300_16 0299_11302018_044756.mp4

Date
11/30/2018
W/O
0742114
Weather
Light Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00665
PipeID
P13351
Time
3:19 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1067
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
21
Purpose
Routine Assessment
Project
20181130MDM_SAN_MARINO_OUTFALL_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
22 in.
Upstream MH
16 0300
Downstream MH
16 0299
Dir. of Survey
Downstream
Length Surveyed
367.9 ft.
Total Length
367.9 ft.
Structural Index
2
Structural Quick
3627
Structural Rating
32
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
32
Pipe schematic from manhole 16 0300 to 16 0299
MH: 16 0300MH: 16 0299downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:45AM4.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - TNIN OUTER LAYER FLAKING8 ft. MGO - General Observation - 22" VCP9.8 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE15.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIGHT23.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active23.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped26.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped26.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open30.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H39.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open61.1 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H62.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped75.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open125.2 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - H126.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open130.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H131.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open158.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H159.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active177.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open203.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open218.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open243.8 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - H275.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open283.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open292.6 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H298.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open298.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8" - Capped316.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open316.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped347.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open359.2 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H359.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H361.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H365.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - H367.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - THIN OUTER LAYER FLAKING367.9 ft. AMH - Downstream Manhole, Survey Ends - 5:30AM

Observation photos (2)

  • General Observation - 22" VCP

    8 ft. - General Observation - 22" VCP

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

    361.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

Observations (40)

DistanceCodeObservation
30.5FLH
26.6TFCCapped
61.1FCH
0MWL
0MWM
4.6SSSTNIN OUTER LAYER FLAKING
126.5TFOpen
159.9TFActive
125.2FCH
203.6TFOpen
298.6TBOpen
62.7TFCCapped
23.2TBActive
316.5TFCCapped
158.9FLH
316.4TBOpen
130.7FLH
177.9TFOpen
131.4TFOpen
361.5FLH
39.6TFOpen
75.6TFOpen
365.2FLH
275.9TFOpen
367.2SSSTHIN OUTER LAYER FLAKING
283.1TFOpen
8MGO22" VCP
15.4FLSLIGHT
359.3FLH
9.8FCHAIRLINE
0AMH4:45AM
292.6FCH
347.4TFOpen
298.7TFCCapped
243.8FCH
218.8TFOpen
23.7TFCCapped
26.6TBOpen
359.2FCH
367.9AMH5:30AM

Properties (6)

custom_field_three
HAIRLINE FRACTURES-HAIRLINE JOINT TO JOINT AT MH
custom_field_two
4
customer
LACSD
datetime
2018-11-30T03:19:40-08:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false