Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 22, 2018, 08:51 AM
  • A 0432_A 0431 _22022018_020144.mp4

Date
02/22/2018
W/O
685104
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00323
PipeID
P08154
Time
12:51 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5463
Sewer Name
A JOA-1A LOS COYOTES WRP INTERCEPTOR
City
SOUTH GATE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Routine Assessment
Project
WO_685104_TV30023_FEB2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Width
63 in.
Upstream MH
A 0432
Downstream MH
A 0431
Dir. of Survey
Downstream
Length Surveyed
255.4 ft.
Total Length
255.4 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
126
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
126
Pipe schematic from manhole A 0432 to A 0431
MH: A 0432MH: A 0431downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 04320 ft. MGO - General Observation - MAG COATING 80% THROUGHOUT.0 ft. MWL - Water Level, 25 %of cross sectional area44.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start255.4 ft. AMH - Downstream Manhole, Survey Ends - A 0431255.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    44.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0AMHA 0432
0MGOMAG COATING 80% THROUGHOUT.
255.4AMHA 0431
0MWL
255.4SAP
44.9SAP

Properties (6)

additional_info
SC346998
custom_field_two
3
customer
LACSD
datetime
2018-02-22T00:51:41-08:00
documentation
PRO PIPE
is_lateral_inspection
false