Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 20, 2017, 07:59 AM
  • 18 1076_18 1075 _20042017_000937.mp4

Date
04/20/2017
W/O
630159
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00682
PipeID
P14935
Time
12:59 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4269
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 5
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_630159_TV18020_APR2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1075
Downstream MH
18 1076
Dir. of Survey
Upstream
Length Surveyed
344.8 ft.
Total Length
344.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 18 1075 to 18 1076
MH: 18 1075MH: 18 1076upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 18 107686.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"128 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"185.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"247.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"342.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start344.8 ft. AMH - Downstream Manhole, Survey Begins - 18 1075344.8 ft. MWL - Water Level, 5 %of cross sectional area344.8 ft. MGO - General Observation - LINER344.8 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK ACTIVE344.8 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
2.1DAGS
0AMH18 1075
216.8TFA
344.8DAGS
258.5TFA
159TFA
0MWL
0MGOLINER
0MGOLATERAL AT MH 3 OCLOCK ACTIVE
97.1TFA
344.8AMH18 1076
0MWM

Properties (8)

additional_info
SC306849
custom_field_two
4
customer
LACSD
datetime
2017-04-20T00:59:11-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP
year_laid
38344