Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 6, 2017, 12:20 PM
  • 18 1100_18 1099 _03062017_042221.mp4

Date
03/06/2017
W/O
624500
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00699
PipeID
P14266
Time
4:20 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4366
Sewer Name
18 SANTA FE STREET RELIEF TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_624500_TV18084_MAR2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 1100
Downstream MH
18 1099
Dir. of Survey
Downstream
Length Surveyed
417.5 ft.
Total Length
417.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2P00
O&M Rating
166
Overall Index
2
Overall Quick
Overall Rating
166
Pipe schematic from manhole 18 1100 to 18 1099
MH: 18 1100MH: 18 1099downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 11000 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start66.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"415.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish417.5 ft. AMH - Downstream Manhole, Survey Ends - 18 1099

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
2DAGS
66.2TBA
415.7DAGS
0AMH18 1100
0MWL
0MWM
417.5AMH18 1099

Properties (7)

additional_info
SC306963
custom_field_two
4
customer
LACSD
datetime
2017-03-06T04:20:09-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
26802