Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 18, 2017, 12:45 AM
  • H 0205_H 0204 _010102_001224.mp4

Date
02/17/2017
W/O
1590881
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00169
PipeID
P11229
Time
4:45 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4320
Sewer Name
H JOINT OUTFALL H - UNIT 2C
City
BELL GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Routine Assessment
Project
WO_624328_TV02168_MAR2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
H 0205
Downstream MH
H 0204
Dir. of Survey
Downstream
Length Surveyed
475 ft.
Total Length
475 ft.
Structural Index
1
Structural Quick
1R00
Structural Rating
93
O&M Index
2
O&M Quick
2Q00
O&M Rating
180
Overall Index
1
Overall Quick
Overall Rating
273
Pipe schematic from manhole H 0205 to H 0204
MH: H 0205MH: H 0204downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 02059.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start9.1 ft. SRI - Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: YES, Start39.1 ft. MGO - General Observation - MAG COATING459.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish474.1 ft. SRI - Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish475 ft. AMH - Downstream Manhole, Survey Ends - H 0204

Observations (9)

DistanceCodeObservation
0MWM
474.1SRI
475AMHH 0204
0MWL
459.1DAGS
39.1MGOMAG COATING
9.1DAGS
0AMHH 0205
9.1SRI

Properties (6)

additional_info
SC318734
custom_field_two
3
customer
LACSD
datetime
2017-02-17T16:45:07-08:00
documentation
PROPIPE
is_lateral_inspection
false