Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 27, 2018, 05:36 PM
  • 22 0750_22 0749_11272018_105346.mp4

Date
11/27/2018
W/O
0741128
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00821
PipeID
P17107
Time
9:36 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
G7863
Sewer Name
22 PUDDINGSTONE TRUNK, SECTS 1&2
City
SAN DIMAS
Loc. details
Building
Location Code
J
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
23
Purpose
Maintenance Related
Project
20181127DF_PUDDINGSTONE_TRUNK_SECTS_1_2
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0750
Downstream MH
22 0749
Dir. of Survey
Downstream
Length Surveyed
348 ft.
Total Length
348 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 0750 to 22 0749
MH: 22 0750MH: 22 0749downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:52 AM0.1 ft. MWL - Water Level, 10 %of cross sectional area0.1 ft. MGO - General Observation - Peeling & Flaking Throughout The Reach0.1 ft. MWM - Water Mark, 15 %of cross sectional area0.1 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 80% MAG23.5 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"100.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"148.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"196.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"248.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"300.5 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 4"340.9 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: YES, 4"346.6 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 60% MAG348 ft. AMH - Downstream Manhole, Survey Ends - 11:12 AM

Observation photos (1)

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 80% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 80% MAG

Observations (15)

DistanceCodeObservation
300.5TFC
148.1TFC
196.3TFC
100.1TFC
248.3TFC
0.1MWL
2SZ80% MAG
0.1MGOPeeling & Flaking Throughout The Reach
0AMH10:52 AM
346.6SZ60% MAG
23.5TFC
0.1MWM
0.1MGOGREASE THROUGHOUT THE REACH (5%)
340.9TFA
348AMH11:12 AM

Properties (6)

additional_info
POST ROOT EVALUATION ONLY
custom_field_two
4
customer
LACSD
datetime
2018-11-27T09:36:35-08:00
documentation
FRANKLIN, IGNACIO, CASTILLO, RUVALCABA
is_lateral_inspection
false