Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 27, 2018, 10:33 AM
  • 18 0468_18 0467_11272018_023725.mp4

Date
11/27/2018
W/O
O740960
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00691
PipeID
P14322
Time
2:33 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1062
Sewer Name
18 NORTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Capital Improvement Program Assesment
Project
20181126MDM_NORTH_PLANT_OUTFALL_TRUNK
Material
NRCP
Shape
Circular
Height
21 in.
Upstream MH
18 0468
Downstream MH
18 0467
Dir. of Survey
Downstream
Length Surveyed
292.7 ft.
Total Length
292.7 ft.
Structural Index
3
Structural Quick
4223
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
14
Pipe schematic from manhole 18 0468 to 18 0467
MH: 18 0468MH: 18 0467downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:35AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG16.4 ft. MGO - General Observation - MAG COAT 30% START 9:00 TO 3:0025.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open38.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active57 ft. SAM - Surface Aggregate Missing, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG57.3 ft. MGO - General Observation - MAG COAT 80% START67.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open87.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open118.4 ft. SSS - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED122.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active156.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open184.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open206.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active235.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open249.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open270.8 ft. SSS - Surface Spalling, from 09 to 12 o'clock, within 8 inches of joint: YES - PEELED AWAY CONCRETE282 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6" - Open292.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - PEELING CONCRETE SEVERE AGG ATTACHED292.3 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG292.7 ft. AMH - Downstream Manhole, Survey Ends - 3:05AM

Observation photos (7)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 30% START 9:00 TO 3:00

    16.4 ft. - General Observation - MAG COAT 30% START 9:00 TO 3:00

  • Surface Aggregate Missing, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG

    57 ft. - Surface Aggregate Missing, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • General Observation - MAG COAT 80% START

    57.3 ft. - General Observation - MAG COAT 80% START

  • Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED

    118.4 ft. - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED

  • Surface Spalling, from 09 to 12 o'clock, within 8 inches of joint: YES - PEELED AWAY CONCRETE

    270.8 ft. - Surface Spalling, from 09 to 12 o'clock, within 8 inches of joint: YES - PEELED AWAY CONCRETE

Observations (24)

DistanceCodeObservation
292.7AMH3:05AM
206.3TFActive
282TFOpen
118.4SSSPEELING CONCRETE SEVERE AGG ATTACHED
0MWM
122.9TFActive
235.7TFOpen
0AMH2:35AM
184.1TFOpen
57.3MGOMAG COAT 80% START
67.5TBOpen
249.2TFOpen
16.4MGOMAG COAT 30% START 9:00 TO 3:00
292.3SSSPEELING CONCRETE SEVERE AGG ATTACHED
38.7TFActive
292.3SAMSEVERE AGG
0MWL
25.3TFOpen
270.8SSSPEELED AWAY CONCRETE
87.1TFOpen
57SAMSEVERE AGG
2SSSPEELING CONCRETE SEVERE AGG ATTACHED
2SAMSEVERE AGG
156.2TFOpen

Properties (6)

custom_field_three
PEELING CONCRETE SEVERE AGG ATTACHED
custom_field_two
2
customer
LACSD
datetime
2018-11-27T02:33:02-08:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false