Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 21, 2018, 09:53 PM
  • E 0105_E 0104_11212018_135541.mp4

Date
11/21/2018
W/O
0739331
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00031
PipeID
P11332
Time
1:53 PM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7861
Sewer Name
E JOINT OUTFALL E - UNIT 4 RELOCATION
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Maintenance Related
Project
20181121SHO_JOINT_OUTFALL_E_UNIT_4_RELOCATION
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
E 0105
Downstream MH
E 0104
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole E 0105 to E 0104
MH: E 0105MH: E 0104downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - E 01052 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES2 ft. MSA - Survey Abandoned - LOOKING D/S TOWARDS E 104

Observation photos (2)

  • Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - LOOKING D/S TOWARDS E 104

    2 ft. - Survey Abandoned - LOOKING D/S TOWARDS E 104

Observations (5)

DistanceCodeObservation
0MWL
2SAV
2MSALOOKING D/S TOWARDS E 104
0MWM
0AMHE 0105

Properties (6)

custom_field_three
CAN'T GET A GOOD VIEW OF D/S MH
custom_field_two
5
customer
LACSD
datetime
2018-11-21T13:53:49-08:00
documentation
OBREGON, YOUNG, CASTILLO, RUVALCABA
is_lateral_inspection
false