Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 14, 2016, 11:53 AM
  • 19 0145_19 0144_20160314_050344.mp4

Date
03/14/2016
W/O
557968
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00722
PipeID
P15335
Time
4:53 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3223
Sewer Name
19 EAST ARTESIA TRUNK, SECTS 1,2,3,&5
City
CERRITOS, CA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
03
Purpose
Routine Assessment
Project
WO_557968_TV19021_2016MAR
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
19 0144
Downstream MH
19 0145
Dir. of Survey
Upstream
Length Surveyed
257.1 ft.
Total Length
257.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 19 0144 to 19 0145
MH: 19 0144MH: 19 0145upstream0 ft. AMH - Upstream Manhole, Survey Ends - 19 01450 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK1.5 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, at 09 o'clock, , within 8 inches of joint: NO1.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish73.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"76.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"170.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"173.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"252.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start257.1 ft. MWM - Water Mark, 20 %of cross sectional area257.1 ft. MWL - Water Level, 10 %of cross sectional area257.1 ft. AMH - Downstream Manhole, Survey Begins - 19 0144

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    4.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
255.6DAE
0MWM
86.4TFC
180.9TFC
83.8TFC
255.6DAGS
0MWL
0AMH19 0144
183.5TFC
4.7DAGS
257.1AMH19 0145
257.1MGOLATERAL AT MH 9 OCLOCK

Properties (6)

additional_info
SC305313
custom_field_two
4
customer
LACSD
datetime
2016-03-14T04:53:27-07:00
documentation
PRO-PIPE
is_lateral_inspection
false