Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 8, 2018, 09:28 AM
  • 18 0891_18 0890 _05072018_135757.mp4

Date
06/08/2018
W/O
707024
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00709
PipeID
P14742
Time
2:28 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5644
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
WHITTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_707024_TV18101_JUN2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
18 0891
Downstream MH
18 0890
Dir. of Survey
Downstream
Length Surveyed
653.5 ft.
Total Length
653.5 ft.
Structural Index
4
Structural Quick
5A34
Structural Rating
62
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
66
Pipe schematic from manhole 18 0891 to 18 0890
MH: 18 0891MH: 18 0890downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 08912.1 ft. MGO - General Observation - MAGNESIUM COATING START10.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start34 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish34 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start72.5 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO87.1 ft. SRV - Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: NO201 ft. DSGV - Deposits Settled Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start208.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish208.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start239.5 ft. SRV - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO242.2 ft. SRV - Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: NO352.3 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO387.6 ft. SRV - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: NO441.8 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO449.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish449.3 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start501.3 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish501.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start522.2 ft. SRV - Surface Reinforcement Visible, at 09 o'clock, within 8 inches of joint: NO572 ft. LL - Alignment Left, 15 %, Start604.9 ft. SRV - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES642.5 ft. LL - Alignment Left, 15 %, Finish651.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish651.2 ft. DSGV - Deposits Settled Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Finish653.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0890653.5 ft. MGO - General Observation - MAGNESIUM COATING END

Observation photos (15)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    10.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    34 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

    72.5 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: NO

    87.1 ft. - Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    208.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO

    239.5 ft. - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: NO

    242.2 ft. - Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

    352.3 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: NO

    387.6 ft. - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO

    441.8 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    449.3 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    501.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Reinforcement Visible, at 09 o'clock, within 8 inches of joint: NO

    522.2 ft. - Surface Reinforcement Visible, at 09 o'clock, within 8 inches of joint: NO

  • Alignment Left, 15 %, Start

    572 ft. - Alignment Left, 15 %, Start

  • Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES

    604.9 ft. - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES

Observations (29)

DistanceCodeObservation
651.2SAP
208.4SAP
653.5AMH18 0890
0MWM
34SAP
0MWL
10.5SAP
72.5SRV
239.5SRV
0AMH18 0891
651.2DSGV
572LL
34SAV
87.1SRV
2.1MGOMAGNESIUM COATING START
449.3SAP
653.5MGOMAGNESIUM COATING END
208.3SAV
604.9SRV
522.2SRV
352.3SRV
201DSGV
387.6SRV
501.3SRV
441.8SRV
449.3SRV
242.2SRV
642.5LL
501.3SAP

Properties (4)

additional_info
SC359199
custom_field_two
3
customer
LACSD
datetime
2018-06-08T02:28:29-07:00