Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 15, 2018, 08:09 AM
  • 18 0867_18 0866 _03072018_154610.mp4

Date
06/15/2018
W/O
707024
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00709
PipeID
P14719
Time
1:09 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5198
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
35
Purpose
Routine Assessment
Project
WO_707024_TV18101_JUN2018
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
18 0867
Downstream MH
18 0866
Dir. of Survey
Downstream
Length Surveyed
3.6 ft.
Total Length
3.6 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
4
Overall Quick
Overall Rating
14
Pipe schematic from manhole 18 0867 to 18 0866
MH: 18 0867MH: 18 0866downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 08670 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES3.6 ft. MSA - Survey Abandoned - VIEW OF THE D/S SIPHON FROM THE U/S MH3.6 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES3.6 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF THE D/S SIPHON FROM THE U/S MH

    3.6 ft. - Survey Abandoned - VIEW OF THE D/S SIPHON FROM THE U/S MH

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    3.6 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO

    3.6 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO

Observations (7)

DistanceCodeObservation
3.6MSAVIEW OF THE D/S SIPHON FROM THE U/S MH
0MWL
3.6SAP
0AMH18 0867
2DAGS
3.6SRV
0MWM

Properties (4)

additional_info
SC359521
custom_field_two
3
customer
LACSD
datetime
2018-06-15T01:09:15-07:00