Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 20, 2018, 05:01 PM
  • 22 0737_22 0736_11202018_103919.mp4

Date
11/20/2018
W/O
0735394
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00821
PipeID
P17093
Time
9:01 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7859
Sewer Name
22 PUDDINGSTONE TRUNK, SECTS 1&2
City
SAN DIMAS
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
22
Purpose
Capital Improvement Program Assesment
Project
20181120SHO_PUDDINGSTONE_TRUNK_SECTION_1_2
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0737
Downstream MH
22 0736
Dir. of Survey
Downstream
Length Surveyed
332.3 ft.
Total Length
332.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 22 0737 to 22 0736
MH: 22 0737MH: 22 0736downstream0 ft. AMH - Upstream Manhole, Survey Begins - MH 07370 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MGO - General Observation - TWO CAPPED CONN. IN THE MH @ 3 & 95.6 ft. MGO - General Observation - 85% MAG COAT INTACT21.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start207.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"307.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"330 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish332.3 ft. AMH - Downstream Manhole, Survey Ends - MH 0736

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    21.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
307.4TFC
0AMHMH 0737
207.3TF
5.6MGO85% MAG COAT INTACT
0MWM
21.3SAV
0MWL
332.3AMHMH 0736
0MGOTWO CAPPED CONN. IN THE MH @ 3 & 9
330SAV

Properties (7)

additional_info
RFIR
custom_field_three
VISIBLE AGGREGATE
custom_field_two
3
customer
LACSD
datetime
2018-11-20T09:01:04-08:00
documentation
OBREGON, RUVALCABA, CASTILLO
is_lateral_inspection
false