Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2018, 08:25 AM
  • 02 1153_02 1152_11162018_003241.mp4

Date
11/16/2018
W/O
0738919
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00351
PipeID
P02937
Time
12:25 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1054R
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Maintenance Related
Project
20181115MDM_GARFIELD_AVENUE_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
02 1153
Downstream MH
02 1152
Dir. of Survey
Downstream
Length Surveyed
261.5 ft.
Total Length
261.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1600
O&M Rating
6
Overall Index
1
Overall Quick
Overall Rating
6
Pipe schematic from manhole 02 1153 to 02 1152
MH: 02 1153MH: 02 1152downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:30AM9.9 ft. RFJ - Roots Fine Joint, from 01 to 03 o'clock, within 8 inches of joint: YESR - 2%14.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped21.9 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR - 1%49.7 ft. RFJ - Roots Fine Joint, from 09 to 11 o'clock, within 8 inches of joint: YESR - 2%52.5 ft. RFJ - Roots Fine Joint, from 01 to 03 o'clock, within 8 inches of joint: YESR - 2%62.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped86.1 ft. RFJ - Roots Fine Joint, from 03 to 04 o'clock, within 8 inches of joint: YESR - 3%111.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped132.6 ft. RFJ - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YESR - 3%164.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped212.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped237.6 ft. MGO - General Observation - 12" VCP261.1 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN261.5 ft. AMH - Downstream Manhole, Survey Ends - 12:55AM

Observation photos (1)

  • General Observation - 12" VCP

    237.6 ft. - General Observation - 12" VCP

Observations (17)

DistanceCodeObservation
86.1RFJ3%
9.9RFJ2%
0MWM
261.5AMH12:55AM
132.6RFJ3%
237.6MGO12" VCP
164.5TFCCapped
62.8TFCCapped
0MWL
21.9RFJ1%
49.7RFJ2%
111.7TFCCapped
0AMH12:30AM
52.5RFJ2%
212.6TFCCapped
261.1MGOConn. @ Mh, 3 O' Clock. OPEN
14.4TFCCapped

Properties (5)

additional_info
POST ROOT/GREASE CCTV
customer
LACSD
datetime
2018-11-16T00:25:27-08:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false