Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 13, 2018, 08:37 PM
  • 03 0620_03 0480_11132018_131800.mp4

Date
11/13/2018
W/O
0737992
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00391
PipeID
P05273
Time
12:37 PM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7852
Sewer Name
03 PICO AVENUE TRUNK
City
LONG BEACH
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
22
Purpose
Capital Improvement Program Assesment
Project
20181113DF_PICO_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Upstream MH
03 0620
Downstream MH
03 0480
Dir. of Survey
Downstream
Length Surveyed
62.3 ft.
Total Length
62.3 ft.
Structural Index
4
Structural Quick
5242
Structural Rating
23
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
23
Pipe schematic from manhole 03 0620 to 03 0480
MH: 03 0620MH: 03 0480downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:16 PM0.1 ft. MWM - Water Mark, 15 %of cross sectional area0.1 ft. MWL - Water Level, 10 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.2 ft. BVV - Broken Void Visible, from 11 to 12 o'clock, within 8 inches of joint: YES5.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES20.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES20.8 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES60.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish60.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish62 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)62.3 ft. AMH - Downstream Manhole, Survey Ends - 1:43 PM62.3 ft. MGP - General Photograph

Observation photos (7)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken Void Visible, from 11 to 12 o'clock, within 8 inches of joint: YES

    5.2 ft. - Broken Void Visible, from 11 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    5.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    20.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

    20.8 ft. - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Photograph

    62.3 ft. - General Photograph

Observations (14)

DistanceCodeObservation
5.2BVV
60.6SSS
0.1MWM
2CM
62.3AMH1:43 PM
20.8FM
62MGOGREASE THROUGHOUT THE REACH (5%)
0AMH1:16 PM
62.3MGP
0.1MWL
3SSS
20.8B
5.2FM
60.6CM

Properties (6)

custom_field_three
BROKEN PIPE
custom_field_two
1
customer
LACSD
datetime
2018-11-13T12:37:12-08:00
documentation
FRANKLIN, CASTILLO, SHADLER, RUVALCABA
is_lateral_inspection
false