Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 9, 2018, 05:53 PM
  • 03 0213_03 0212_1192018_110127.mp4

Date
11/09/2018
W/O
0723658
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00387
PipeID
P04813
Time
9:53 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7850
Sewer Name
03 NORTH LONG BEACH TRUNK
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
10
Purpose
Routine Assessment
Project
20181109DF_NORTH_LONG_BEACH_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Upstream MH
03 0213
Downstream MH
03 0212
Dir. of Survey
Downstream
Length Surveyed
542 ft.
Total Length
542 ft.
Structural Index
2
Structural Quick
3123
Structural Rating
10
O&M Index
2
O&M Quick
2511
O&M Rating
11
Overall Index
2
Overall Quick
Overall Rating
21
Pipe schematic from manhole 03 0213 to 03 0212
MH: 03 0213MH: 03 0212downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:00 AM0.1 ft. MWL - Water Level, 25 %of cross sectional area0.1 ft. MWM - Water Mark, 30 %of cross sectional area17.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start45.1 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES53.2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES128.1 ft. MGP - General Photograph150.5 ft. MGP - General Photograph167.9 ft. CC - Crack Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES168 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start236.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES236.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 04 o'clock, , within 8 inches of joint: YES266.5 ft. FC - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES, Start271.1 ft. FC - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES, Finish313.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES346.9 ft. MGP - General Photograph488.3 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR488.3 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES541.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish541.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish541.6 ft. MGO - General Observation - Grease Throughout The Reach (5%)542 ft. AMH - Downstream Manhole, Survey Ends - 11:47 AM

Observation photos (16)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    45.1 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    53.2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • General Photograph

    128.1 ft. - General Photograph

  • General Photograph

    150.5 ft. - General Photograph

  • Crack Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES

    167.9 ft. - Crack Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    168 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    236.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, at 04 o'clock,  , within 8 inches of joint: YES

    236.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, at 04 o'clock, , within 8 inches of joint: YES

  • Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES, Start

    266.5 ft. - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES, Finish

    271.1 ft. - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES, Finish

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    313.1 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • General Photograph

    346.9 ft. - General Photograph

  • Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR

    488.3 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    488.3 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • General Observation - Grease Throughout The Reach (5%)

    541.6 ft. - General Observation - Grease Throughout The Reach (5%)

Observations (22)

DistanceCodeObservation
0.1MWL
150.5MGP
488.3RFJ
0.1MWM
17.6SSS
346.9MGP
128.1MGP
541.6SSS
271.1FC
45.1DAE
266.5FC
488.3DAE
168CM
541.6CM
0AMH10:00 AM
167.9CC
53.2DAE
541.6MGOGrease Throughout The Reach (5%)
236.1CL
236.1DAGS
542AMH11:47 AM
313.1DAE

Properties (4)

customer
LACSD
datetime
2018-11-09T09:53:08-08:00
documentation
FRANKLIN, CASTILLO, RUVALCABA, YOUNG
is_lateral_inspection
false