22 1377_22 0174 _11022018306_033923.mp4
0.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
5.1 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
5.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
5.1 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start
143.7 ft. - Tap Break-In Intruding, at 12 o'clock, -, #v, within 8 inches of joint: NO, 6", 3"
290.7 ft. - General Observation - COCKROACHES IN MANHOLE
| Distance | Code | Observation |
|---|---|---|
| 0 | MWL | — |
| 0 | MWM | — |
| 290.7 | MGO | COCKROACHES IN MANHOLE |
| 103.1 | TBA | — |
| 0 | MGO | ACTIVE CONNECTION AT MH 4 O'CLOCK |
| 292.5 | AMH | 22 0174 |
| 143.7 | TBI | — |
| 5.1 | SAP | — |
| 290.7 | SAP | — |
| 285 | SRV | — |
| 5.1 | SSS | — |
| 290.7 | SSS | — |
| 0.7 | DAGS | — |
| 290.7 | DAGS | — |
| 5.1 | SRV | — |
| 0 | AMH | 22 1377 |