- Date
- 10/05/2018
- W/O
- 729980
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00183
- PipeID
- P10947
- Time
- 7:45 AM
- Certificate
- U-115-06022794
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K5913
- Sewer Name
- H JOINT OUTFALL H - UNIT 7B
- City
- CITY OF INDUSTRY
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 35
- Purpose
- Routine Assessment
- Project
- RFIR_WO_729980_TV15231_OCT2018
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Width
- 39 in.
- Upstream MH
- H 0522
- Downstream MH
- H 0521
- Dir. of Survey
- Downstream
- Length Surveyed
- 422.7 ft.
- Total Length
- 422.7 ft.
- Structural Index
- 3
- Structural Quick
- 3P00
- Structural Rating
- 249
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 251
Pipe schematic from manhole H 0522 to H 0521 Observation photos (6)

0 ft. - General Observation - COCKROACHES IN MANHOLE

3.2 ft. - General Observation - MAG COAT

3.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

407.2 ft. - Vermin - Rat, within 8 inches of joint: NO, 1

422.5 ft. - General Observation - CONNECTION AT THE MH 3 O'CLOCK

422.7 ft. - General Observation - COCKROACHES IN MANHOLE