- Date
- 10/15/2018
- W/O
- 729712
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00174
- PipeID
- P10750
- Time
- 12:56 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6149
- Sewer Name
- H JOINT OUTFALL H - UNIT 3
- City
- PICO RIVERA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_729712_TV02323_OCT2018
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Width
- 57 in.
- Upstream MH
- H 0295
- Downstream MH
- H 0294
- Dir. of Survey
- Downstream
- Length Surveyed
- 296.1 ft.
- Total Length
- 296.1 ft.
- Structural Index
- 4
- Structural Quick
- 5K3K
- Structural Rating
- 472
- O&M Index
- 3
- O&M Quick
- 3K00
- O&M Rating
- 177
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 649
Pipe schematic from manhole H 0295 to H 0294 Observation photos (3)

2.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start - HEAVY SLUDGE

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start