Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 15, 2018, 10:27 AM
  • H 0097_H 0096_15102018_034211.mp4

Date
10/15/2018
W/O
729709
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00165
PipeID
P10549
Time
3:27 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6150
Sewer Name
H JOINT OUTFALL H - UNIT 1F
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_729709_TV01220_OCT2018
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
H 0096
Downstream MH
H 0097
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0096 to H 0097
MH: H 0096MH: H 0097upstream0 ft. MSA - Survey Abandoned - UP LEG OF THE D/S SIPHON0 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES2.1 ft. MWL - Water Level, 15 %of cross sectional area2.1 ft. MWM - Water Mark, 30 %of cross sectional area2.1 ft. AMH - Downstream Manhole, Survey Begins - H 0096

Observation photos (2)

  • Survey Abandoned - UP LEG OF THE D/S SIPHON

    2.1 ft. - Survey Abandoned - UP LEG OF THE D/S SIPHON

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
0MWL
0MWM
2.1MSAUP LEG OF THE D/S SIPHON
2.1SAP
0AMHH 0096

Properties (4)

additional_info
SC365217
custom_field_two
2
customer
LACSD
datetime
2018-10-15T03:27:03-07:00