Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 10, 2018, 10:11 AM
  • C 0653_C 0652 _10102018_031432.mpg

Date
10/10/2018
W/O
729692
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00266
PipeID
P23919
Time
3:11 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6142
Sewer Name
C JOINT OUTFALL C - UNIT 3F
City
long beach
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_729692_TV03162_OCT2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
C 0653
Downstream MH
C 0652
Dir. of Survey
Downstream
Length Surveyed
307.2 ft.
Total Length
307.2 ft.
Structural Index
2
Structural Quick
3121
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole C 0653 to C 0652
MH: C 0653MH: C 0652downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 06530 ft. MWL - Water Level, 15 %of cross sectional area26.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES35.1 ft. CC - Crack Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES47.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start303.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish307.2 ft. AMH - Downstream Manhole, Survey Ends - C 0652

Observation photos (3)

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    26.9 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES

    35.1 ft. - Crack Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    47.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWM
35.1CC
0AMHC 0653
47.4CM
303.1CM
0MWL
26.9CL
307.2AMHC 0652

Properties (4)

additional_info
SC365209
customer
LACSD
datetime
2018-10-10T03:11:36-07:00
year_laid
37482