Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 16, 2018, 09:12 PM
  • 08 0596_D 0008 _16102018_141400.mp4

Date
10/16/2018
W/O
729477
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00025
PipeID
P00530
Time
2:12 PM
Certificate
U-109-7948
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6062
Sewer Name
08 216TH STREET RELOCATION TRUNK
City
TORRANCE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_729477_TV08101_OCT2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
08 0596
Downstream MH
D 0008
Dir. of Survey
Downstream
Length Surveyed
713.4 ft.
Total Length
713.4 ft.
Structural Index
5
Structural Quick
5[00
Structural Rating
705
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
709
Pipe schematic from manhole 08 0596 to D 0008
MH: 08 0596MH: D 0008downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 05962 ft. MGO - General Observation - MAGNEZIUM H.O COATING START9.4 ft. SRCZ - Surface Reinforcement Corroded Unknown, from 09 to 03 o'clock, within 8 inches of joint: YES, Start713.3 ft. SRCZ - Surface Reinforcement Corroded Unknown, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish713.4 ft. AMH - Downstream Manhole, Survey Ends - D 0008

Observation photos (1)

  • Surface Reinforcement Corroded Unknown, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    9.4 ft. - Surface Reinforcement Corroded Unknown, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
9.4SRCZ
713.4AMHD 0008
713.3SRCZ
2MGOMAGNEZIUM H.O COATING START
0MWM
0MWL
0AMH08 0596

Properties (3)

custom_field_two
4
customer
LACSD
datetime