Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 15, 2018, 09:10 AM
  • 22 1015_22 1014_15102018_021029.mp4

Date
10/15/2018
W/O
729443
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00819
PipeID
P17384
Time
2:10 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6167
Sewer Name
22 LORAINE TRUNK
City
GLENDORA
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_729443_TV22159_OCT2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 1015
Downstream MH
22 1014
Dir. of Survey
Downstream
Length Surveyed
390.3 ft.
Total Length
390.3 ft.
Structural Index
3
Structural Quick
3N00
Structural Rating
231
O&M Index
2
O&M Quick
362O
O&M Rating
189
Overall Index
2
Overall Quick
Overall Rating
420
Pipe schematic from manhole 22 1015 to 22 1014
MH: 22 1015MH: 22 1014downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 10152 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - MAG COATING THROUGHOUT 70%17 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"68.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"145.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"181.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"218 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"248.4 ft. RFJ - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YESR261.4 ft. RML - Roots Medium Lateral, from 01 to 08 o'clock, 40 %, within 8 inches of joint: YES262.1 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS308.6 ft. RFJ - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YESR312.6 ft. RMJ - Roots Medium Joint, from 08 to 03 o'clock, 20 %, within 8 inches of joint: YESR316.6 ft. RFJ - Roots Fine Joint, from 08 to 12 o'clock, within 8 inches of joint: YESR318.1 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS318.2 ft. RML - Roots Medium Lateral, from 01 to 05 o'clock, 25 %, within 8 inches of joint: YES333 ft. RMJ - Roots Medium Joint, from 02 to 06 o'clock, 25 %, within 8 inches of joint: YESR345.1 ft. RMJ - Roots Medium Joint, from 03 to 06 o'clock, 25 %, within 8 inches of joint: YESR349.4 ft. RFJ - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YESR, Start369.9 ft. RML - Roots Medium Lateral, from 12 to 05 o'clock, 35 %, within 8 inches of joint: YES369.9 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS388.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish388.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish388.5 ft. RFJ - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YESR, Finish390.3 ft. AMH - Downstream Manhole, Survey Ends - 22 1014

Observation photos (13)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YESR

    248.4 ft. - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YESR

  • Roots Medium Lateral, from 01 to 08 o'clock, 40 %, within 8 inches of joint: YES

    261.4 ft. - Roots Medium Lateral, from 01 to 08 o'clock, 40 %, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

    262.1 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS

  • Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YESR

    308.6 ft. - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YESR

  • Roots Medium Joint, from 08 to 03 o'clock, 20 %, within 8 inches of joint: YESR

    312.6 ft. - Roots Medium Joint, from 08 to 03 o'clock, 20 %, within 8 inches of joint: YESR

  • Roots Fine Joint, from 08 to 12 o'clock, within 8 inches of joint: YESR

    316.6 ft. - Roots Fine Joint, from 08 to 12 o'clock, within 8 inches of joint: YESR

  • Roots Medium Lateral, from 01 to 05 o'clock, 25 %, within 8 inches of joint: YES

    318.2 ft. - Roots Medium Lateral, from 01 to 05 o'clock, 25 %, within 8 inches of joint: YES

  • Roots Medium Joint, from 02 to 06 o'clock, 25 %, within 8 inches of joint: YESR

    333 ft. - Roots Medium Joint, from 02 to 06 o'clock, 25 %, within 8 inches of joint: YESR

  • Roots Medium Joint, from 03 to 06 o'clock, 25 %, within 8 inches of joint: YESR

    345.1 ft. - Roots Medium Joint, from 03 to 06 o'clock, 25 %, within 8 inches of joint: YESR

  • Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YESR, Start

    349.4 ft. - Roots Fine Joint, from 03 to 09 o'clock, within 8 inches of joint: YESR, Start

  • Roots Medium Lateral, from 12 to 05 o'clock, 35 %, within 8 inches of joint: YES

    369.9 ft. - Roots Medium Lateral, from 12 to 05 o'clock, 35 %, within 8 inches of joint: YES

Observations (29)

DistanceCodeObservation
333RMJ
261.4RML
145.5TF
369.9RML
2SAP
262.1TFDROOTS
248.4RFJ
2DAGS
0MWM
312.6RMJ
218TFC
318.1TFDROOTS
345.1RMJ
308.6RFJ
369.9TFDROOTS
17TFA
349.4RFJ
2MGOMAG COATING THROUGHOUT 70%
318.2RML
388.5SAP
0MGOCOCKROACHES IN MANHOLE
388.5DAGS
68.9TF
316.6RFJ
181.5TFA
388.5RFJ
0MWL
0AMH22 1015
390.3AMH22 1014

Properties (4)

additional_info
SC365135
custom_field_two
2
customer
LACSD
datetime
2018-10-15T02:10:21-07:00