Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 30, 2017, 09:52 AM
  • 14 0098_14 0097A _30032017_025244.mpg

Date
03/30/2017
W/O
624327
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00577
PipeID
P18117
Time
2:52 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4404
Sewer Name
14 TRUNK "A"
City
LANCASTER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
18
Purpose
Routine Assessment
Project
WO_624327_TV14017_MAR2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
14 0098
Downstream MH
14 0097A
Dir. of Survey
Downstream
Length Surveyed
310.1 ft.
Total Length
310.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 14 0098 to 14 0097A
MH: 14 0098MH: 14 0097Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 14 00980 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. MMC - Material Change, Vitrified clay pipe23.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"50.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"78 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"105.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"128.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"151.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"201.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"224.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"251.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"278.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"305.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"310.1 ft. AMH - Downstream Manhole, Survey Ends - 14 0097A310.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observations (18)

DistanceCodeObservation
50.6TFC
201.6TFC
251.4TFC
278.6TFC
0AMH14 0098
128.3TFC
0MWM
0MWL
78TFC
305.7TFC
105.4TFC
310.1AMH14 0097A
310.1MGOCONNECTION AT MH 3 O'CLOCK
174.2TFC
2MMC
224.4TFC
151.3TFC
23.7TFC

Properties (4)

additional_info
SC345163
custom_field_two
4
customer
LACSD
datetime
2017-03-30T02:52:38-07:00