05 0453_05 0452_1172018_004738.mp4
2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE
8.1 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
24.2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO
111 ft. - Water Level, 40 %of cross sectional area
116.4 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
141.4 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish
| Distance | Code | Observation |
|---|---|---|
| 141.4 | DAGS | — |
| 2 | DAGS | — |
| 24.2 | DAGS | — |
| 141.4 | SSS | FLAKING CONCRETE |
| 2 | SAV | SEVERE AGG SPORATIC |
| 0 | AMH | 12:40AM |
| 0 | MWM | — |
| 2 | SSS | FLAKING CONCRETE |
| 116.4 | SAV | SEVERE AGG SPORATIC |
| 0 | MWL | — |
| 141.9 | AMH | 1:00AM |
| 141.4 | SAV | SEVERE AGG VERY SPORATIC |
| 8.1 | SAV | SEVERE AGG SPORATIC |
| 111 | MWL | — |