Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 6, 2018, 08:46 AM
  • H 0405_H 0906_1162018_010202.mp4

Date
11/06/2018
W/O
0729413
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00177
PipeID
P21281
Time
12:46 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1041
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
02
Purpose
Routine Assessment
Project
20181106MDM_JOINT_OUTFALL_H_UNIT_5A
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Upstream MH
H 0906
Downstream MH
H 0405
Dir. of Survey
Upstream
Length Surveyed
40 ft.
Total Length
40 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole H 0906 to H 0405
MH: H 0906MH: H 0405upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:00AM GATE DOWN26.4 ft. MGP - General Photograph - HOBAS PIPE30.3 ft. MGO - General Observation - 54" HOBAS PIPE38 ft. MGO - General Observation - 54" HOBAS PIPE39 ft. MGO - General Observation - MH#H405 GATE DOWN39 ft. MGO - General Observation - MH # H906 LOCATED IN ROAD NOT GRASS AREA40 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN 6" PVC IN STACK40 ft. MWL - Water Level, 0 %of cross sectional area - DRY LINE40 ft. MWM - Water Mark, 20 %of cross sectional area40 ft. AMH - Downstream Manhole, Survey Begins - 12:45AM40 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active

Observation photos (4)

  • General Observation - 54" HOBAS PIPE

    2 ft. - General Observation - 54" HOBAS PIPE

  • General Observation - 54" HOBAS PIPE

    9.7 ft. - General Observation - 54" HOBAS PIPE

  • General Photograph - HOBAS PIPE

    13.6 ft. - General Photograph - HOBAS PIPE

  • Upstream Manhole, Survey Ends - 1:00AM GATE DOWN

    40 ft. - Upstream Manhole, Survey Ends - 1:00AM GATE DOWN

Observations (11)

DistanceCodeObservation
0MGOConn. @ Mh, 3 O' Clock. OPEN 6" PVC IN STACK
1MGOMH#H405 GATE DOWN
40AMH1:00AM GATE DOWN
13.6MGPHOBAS PIPE
0MWLDRY LINE
9.7MGO54" HOBAS PIPE
2MGO54" HOBAS PIPE
0MWM
1MGOMH # H906 LOCATED IN ROAD NOT GRASS AREA
0AMH12:45AM
0MGOConn. @ Mh, 9 O' Clock. Active

Properties (5)

additional_info
REVERSE INSPECTION
customer
LACSD
datetime
2018-11-06T00:46:31-08:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false