Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 5, 2018, 05:44 PM
  • H 0638_H 0637_1152018_094744.mp4

Date
11/05/2018
W/O
0736432
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00192
PipeID
P11044
Time
9:44 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7845
Sewer Name
H JOINT OUTFALL H - UNIT 8J
City
BALDWIN PARK
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Capital Improvement Program Assesment
Project
20181105SHO_JOINT_OUTFALL_H_UNIT_8J
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
H 0637
Downstream MH
H 0638
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0637 to H 0638
MH: H 0637MH: H 0638upstream0 ft. MSA - Survey Abandoned - VIEW OF THE UPLEG OF THE N/W BARREL0 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES2 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. MWL - Water Level, 25 %of cross sectional area2 ft. AMH - Downstream Manhole, Survey Begins - N/W BARREL, UPLEG OF SIPHON

Observation photos (2)

  • Survey Abandoned - VIEW OF THE UPLEG OF THE N/W BARREL

    2 ft. - Survey Abandoned - VIEW OF THE UPLEG OF THE N/W BARREL

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
2MSAVIEW OF THE UPLEG OF THE N/W BARREL
0MWM
2SAV
0MWL
0AMHN/W BARREL, UPLEG OF SIPHON

Properties (6)

custom_field_three
AGGREGATE IS VISIBLE
custom_field_two
3
customer
LACSD
datetime
2018-11-05T09:44:00-08:00
documentation
OBREGON, YOUNG, RUVALCABA, CASTILLO
is_lateral_inspection
false