Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 12, 2017, 05:48 AM
  • 18 0001_18 0784 _11072017_224836.mp4

Date
07/11/2017
W/O
641208
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00713
PipeID
P13816
Time
10:48 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4641
Sewer Name
18 WALNUT WAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_641208_TV18059_JUN2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0001
Downstream MH
18 0784
Dir. of Survey
Downstream
Length Surveyed
299.5 ft.
Total Length
299.7 ft.
Structural Index
3
Structural Quick
3K21
Structural Rating
179
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
179
Pipe schematic from manhole 18 0001 to 18 0784
MH: 18 0001MH: 18 0784downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 00010.1 ft. MWM - Water Mark, 30 %of cross sectional area2.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES13.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"67.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"101.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"116.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"125.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"190.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"209 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"224.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"285.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"295.1 ft. MMC - Material Change, Vitrified clay pipe295.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish299.5 ft. MGO - General Observation - CONNECTION AT MH 12 ACTIVE299.5 ft. MGO - General Observation - CONNECTION AT MH 3 ACTIVE299.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0784

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Material Change, Vitrified clay pipe

    295.1 ft. - Material Change, Vitrified clay pipe

Observations (19)

DistanceCodeObservation
190.2TF
224.1TF
209TF
125.9TF
285.3TF
299.6AMH18 0784
295.1MMC
7SSS
0MWL
0AMH18 0001
299.5MGOCONNECTION AT MH 12 ACTIVE
0.1MWM
67.9TF
299.5MGOCONNECTION AT MH 3 ACTIVE
295.1SAV
101.4TF
116.6TF
13.6TF
2.3SAV

Properties (6)

additional_info
SC345501
custom_field_two
2
customer
LACSD
datetime
2017-07-11T22:48:30-07:00
documentation
PROPIPE
is_lateral_inspection
false