Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 11, 2017, 08:07 AM
  • 18 0027_18 0026 _11072017_010816.mp4

Date
07/11/2017
W/O
641208
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00713
PipeID
P13843
Time
1:07 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4640
Sewer Name
18 WALNUT WAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
15
Purpose
Routine Assessment
Project
WO_641208_TV18059_JUN2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0026
Downstream MH
18 0027
Dir. of Survey
Upstream
Length Surveyed
88.2 ft.
Total Length
88.2 ft.
Structural Index
3
Structural Quick
3B21
Structural Rating
54
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
54
Pipe schematic from manhole 18 0026 to 18 0027
MH: 18 0026MH: 18 0027upstream0 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 18 00274.8 ft. CC - Crack Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES47.7 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES72.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"86 ft. MGO - General Observation - MAG COAT86 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start88.2 ft. MWM - Water Mark, 10 %of cross sectional area88.2 ft. AMH - Downstream Manhole, Survey Begins - 18 002688.2 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE88.2 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (3)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    40.5 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES

    83.4 ft. - Crack Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
2.2MGOMAG COAT
88.2SAV
88.2MGOCONNECTION AT MH 3 O'CLOCK
83.4CC
0MWM
2.2SAV
88.2AMH18 0027
0AMH18 0026
0MGOCONNECTION AT MH 9 ACTIVE
15.3TFC
40.5CL
0MWL

Properties (6)

additional_info
SC345386
custom_field_two
3
customer
LACSD
datetime
2017-07-11T01:07:41-07:00
documentation
PROPIPE
is_lateral_inspection
false