Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2017, 06:24 AM
  • 02 0032A_02 0032_21062017_003502.mp4

Date
06/20/2017
W/O
640701
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00234
PipeID
P03064
Time
11:24 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4623
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Routine Assessment
Project
WO_640701_TV02341_JUN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0032
Downstream MH
02 0032A
Dir. of Survey
Upstream
Length Surveyed
178.8 ft.
Total Length
178.8 ft.
Structural Index
3
Structural Quick
3E21
Structural Rating
95
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
96
Pipe schematic from manhole 02 0032 to 02 0032A
MH: 02 0032MH: 02 0032Aupstream0 ft. AMH - Downstream Manhole, Survey Ends - 02 0032A0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish28.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR34.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"151.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start165.5 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES174.3 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES178.8 ft. AMH - Downstream Manhole, Survey Begins - 02 0032178.8 ft. MWL - Water Level, 15 %of cross sectional area178.8 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (4)

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    4.5 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    13.3 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    27.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

    150.4 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

Observations (11)

DistanceCodeObservation
178.8AMH02 0032A
150.4RFJ
178.8MGOCONNECTION AT THE MH 9 O'CLOCK
0AMH02 0032
144TFC
0MWL
175.8CM
4.5CM
13.3CL
27.6CM
0MWM

Properties (6)

additional_info
SC345338
custom_field_two
2
customer
LACSD
datetime
2017-06-20T23:24:48-07:00
documentation
PROPIPE
is_lateral_inspection
false