Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2016, 08:32 AM
  • 02 1404_02 1403_20160509_020229.mp4

Date
05/09/2016
W/O
568667
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00349
PipeID
P02975
Time
1:32 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3367
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_568667_TV02220_MAY2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Upstream MH
02 1404
Downstream MH
02 1403
Dir. of Survey
Downstream
Length Surveyed
833.6 ft.
Total Length
833.6 ft.
Structural Index
3
Structural Quick
563a
Structural Rating
537
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
537
Pipe schematic from manhole 02 1404 to 02 1403
MH: 02 1404MH: 02 1403downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 14042.5 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start2.6 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO, Start12.5 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO94.6 ft. SRP - Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO611.6 ft. SRP - Surface Reinforcement Projecting, from 01 to 03 o'clock, within 8 inches of joint: NO667.9 ft. SAP - Surface Aggregate Projecting, from 09 to 12 o'clock, within 8 inches of joint: NO685.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start808.4 ft. SMW - Surface Missing Wall, from 09 to 10 o'clock, within 8 inches of joint: NO833.5 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish833.5 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish833.5 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish833.6 ft. AMH - Downstream Manhole, Survey Ends - 02 1403

Observation photos (8)

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

    2.5 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

    2.6 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO

    12.5 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO

    94.6 ft. - Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Projecting, from 01 to 03 o'clock, within 8 inches of joint: NO

    611.6 ft. - Surface Reinforcement Projecting, from 01 to 03 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Projecting, from 09 to 12 o'clock, within 8 inches of joint: NO

    667.9 ft. - Surface Aggregate Projecting, from 09 to 12 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

    685.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

  • Surface Missing Wall, from 09 to 10 o'clock, within 8 inches of joint: NO

    808.4 ft. - Surface Missing Wall, from 09 to 10 o'clock, within 8 inches of joint: NO

Observations (15)

DistanceCodeObservation
2.6SAP
833.5SRC
808.4SMW
611.6SRP
0MWM
833.6AMH02 1403
685.2SRC
12.5SRC
833.5SRV
0MWL
94.6SRP
833.5SAP
2.5SRV
0AMH02 1404
667.9SAP

Properties (6)

additional_info
SC300364
custom_field_two
1
customer
LACSD
datetime
2016-05-09T01:32:33-07:00
documentation
PROPIPE
is_lateral_inspection
false