05 1874_05 1873_8242017_041710.mp4
8 ft. - General Observation - 8" VCP
11.8 ft. - Surface Spalling, from 06 to 05 o'clock, within 8 inches of joint: YES, Start - SPORATIC SURFACE PEELING
71.2 ft. - Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: YES
97.9 ft. - Surface Spalling, from 06 to 08 o'clock, within 8 inches of joint: NO
215.1 ft. - Surface Spalling, from 06 to 10 o'clock, within 8 inches of joint: YES
324 ft. - General Photograph - SPALLING
324 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, - PIPE DEFECT OR SUFACE PEELING
325 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES - JOINT TO JOINT
| Distance | Code | Observation |
|---|---|---|
| 257.8 | TFC | Capped |
| 0 | MWM | — |
| 41.1 | TB | Active |
| 0 | AMH | 4:15AM |
| 18.7 | TF | Active |
| 195.5 | TF | Active |
| 325 | SSS | JOINT TO JOINT |
| 57.4 | TFC | Capped |
| 11.8 | SSS | SPORATIC SURFACE PEELING |
| 215.1 | SSS | — |
| 3 | FL | HAIRLINE |
| 93.1 | TF | Open |
| 284.7 | TF | Open |
| 234 | TF | Open |
| 71.2 | SSS | — |
| 8 | MGO | 8" VCP |
| 97.9 | SSS | — |
| 0 | MWL | — |
| 154.9 | TF | Open |
| 342 | SSS | SPORATIC SUFACE PEELING |
| 324 | MGP | SPALLING |
| 324 | SSS | PIPE DEFECT OR SUFACE PEELING |
| 342.6 | AMH | 5:00AM |
| 131.2 | FC | SLIGHT,SMALL CHIP AREA |