Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 15, 2017, 09:51 AM
  • 01 0261_01 0260_15062017_030926.mp4

Date
06/15/2017
W/O
640730
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00218
PipeID
P01307
Time
2:51 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3971-SC342128
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_640730_TV01204_JUN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0261
Downstream MH
01 0260
Dir. of Survey
Downstream
Length Surveyed
321.8 ft.
Total Length
321.8 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
4121
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
11
Pipe schematic from manhole 01 0261 to 01 0260
MH: 01 0261MH: 01 0260downstream0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 02610 ft. MWL - Water Level, 15 %of cross sectional area6.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start16.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start60.7 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 6"60.7 ft. RFC - Roots Fine Connection, at 01 o'clock100.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"139.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6"181.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6"221.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6"260.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"318.6 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish318.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish321.4 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK321.8 ft. AMH - Downstream Manhole, Survey Ends - 01 0260

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    6.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    16.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Connection, at 01 o'clock

    60.7 ft. - Roots Fine Connection, at 01 o'clock

Observations (16)

DistanceCodeObservation
139.5TF
0MWM
100.1TFC
0AMH01 0261
6.8DAGS
318.6FM
60.7TB
60.7RFC
260.4TFC
16.5FM
318.6DAGS
321.8AMH01 0260
321.4MGOCONNECTION AT MH 3 OCLOCK
221.3TF
181.6TF
0MWL

Properties (3)

custom_field_two
2
customer
LACSD
datetime
2017-06-15T02:51:11-07:00