Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 15, 2016, 06:17 AM
  • 19 0133A_19 0133_20160314_233657.mp4

Date
03/14/2016
W/O
557968
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00722
PipeID
P15323
Time
11:17 PM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3224
Sewer Name
19 EAST ARTESIA TRUNK, SECTS 1,2,3,&5
City
CERRITOS, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
05
Purpose
Routine Assessment
Project
WO_557968_TV19021_2016MAR
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
19 0133A
Downstream MH
19 0133
Dir. of Survey
Downstream
Length Surveyed
254.1 ft.
Total Length
254.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2400
O&M Rating
8
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 19 0133A to 19 0133
MH: 19 0133AMH: 19 0133downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 19 0133A0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK0 ft. MWM - Water Mark, 30 %of cross sectional area3.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start11.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"69.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"82.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES84 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"115.9 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES125.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, at 10 o'clock, , within 8 inches of joint: YES133 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4", 4"141.4 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"191.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"252.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish254.1 ft. MGO - General Observation - LATERAL AT MH12 OCLOCK254.1 ft. AMH - Downstream Manhole, Survey Ends - 19 0133254.1 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK

Observations (18)

DistanceCodeObservation
3.3DAGS
141.4TBA
82.3DAGS
254.1MGOLATERAL AT MH12 OCLOCK
84TFC
133TF
191.1TFC
0MWL
11.5TFC
125.7DAE
115.9DAE
0AMH19 0133A
69.4TFC
0MGOLATERAL AT MH 3 OCLOCK
254.1AMH19 0133
0MWM
254.1MGOLATERAL AT MH 3 OCLOCK
252.2DAGS

Properties (4)

additional_info
SC305315
custom_field_two
4
customer
LACSD
datetime
2016-03-14T23:17:13-07:00