Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 28, 2017, 07:20 AM
  • 19 0295_19 0217_28062017_002106.mp4

Date
06/28/2017
W/O
640867
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00718
PipeID
P15187
Time
12:20 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4628
Sewer Name
19 ARTESIA-CERRITOS TRUNK
City
ARTESIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
WO_640867_TV19059_JUN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
19 0295
Downstream MH
19 0217
Dir. of Survey
Downstream
Length Surveyed
246.9 ft.
Total Length
246.9 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
138
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
140
Pipe schematic from manhole 19 0295 to 19 0217
MH: 19 0295MH: 19 0217downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 19 02950.1 ft. MGO - General Observation - CONNECTION AT MH 6 ACTIVE0.1 ft. MGO - General Observation - CONNECTION AT MH 5 ACTIVE0.1 ft. MGO - General Observation - CONNECTION AT MH 4 ACTIVE0.1 ft. MGO - General Observation - CONNECTION AT MH 7 ACTIVE8.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start37.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"64.1 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"96.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"101 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"111.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"139 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"178 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"180.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"241.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish246.9 ft. AMH - Downstream Manhole, Survey Ends - 19 0217246.9 ft. MGO - General Observation - CONNECTION AT MH 9 ACTIVE

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    64.1 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

Observations (19)

DistanceCodeObservation
180.2TF
246.9AMH19 0217
139TF
0.1MGOCONNECTION AT MH 6 ACTIVE
0.1MGOCONNECTION AT MH 5 ACTIVE
0.1MGOCONNECTION AT MH 4 ACTIVE
37.2TFC
178TF
64.1TBI
0MWL
0.1MGOCONNECTION AT MH 7 ACTIVE
111.8TF
96.6TF
246.9MGOCONNECTION AT MH 9 ACTIVE
0MWM
8.7CM
0AMH19 0295
101TF
241.2CM

Properties (4)

additional_info
SC345345
custom_field_two
3
customer
LACSD
datetime
2017-06-28T00:20:34-07:00