02 1404_02 1403_20160509_020229.mp4
2.5 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start
2.6 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO, Start
12.5 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO
94.6 ft. - Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO
611.6 ft. - Surface Reinforcement Projecting, from 01 to 03 o'clock, within 8 inches of joint: NO
667.9 ft. - Surface Aggregate Projecting, from 09 to 12 o'clock, within 8 inches of joint: NO
685.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start
808.4 ft. - Surface Missing Wall, from 09 to 10 o'clock, within 8 inches of joint: NO
| Distance | Code | Observation |
|---|---|---|
| 2.6 | SAP | — |
| 833.5 | SRC | — |
| 808.4 | SMW | — |
| 611.6 | SRP | — |
| 0 | MWM | — |
| 833.6 | AMH | 02 1403 |
| 685.2 | SRC | — |
| 12.5 | SRC | — |
| 833.5 | SRV | — |
| 0 | MWL | — |
| 94.6 | SRP | — |
| 833.5 | SAP | — |
| 2.5 | SRV | — |
| 0 | AMH | 02 1404 |
| 667.9 | SAP | — |