Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 16, 2016, 09:46 AM
  • 05 1652_05 1651 _061616_024639.mpg

Date
06/16/2016
W/O
563399
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00539
PipeID
P06875
Time
2:46 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3398
Sewer Name
05 WEST TORRANCE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
30
Purpose
Routine Assessment
Project
WO_563399_TV05132_JUNE2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1651
Downstream MH
05 1652
Dir. of Survey
Upstream
Length Surveyed
381.4 ft.
Total Length
381.4 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
216
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
218
Pipe schematic from manhole 05 1651 to 05 1652
MH: 05 1651MH: 05 1652upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 16520.2 ft. MGO - General Observation - CONNECTION AT THE MH 3 O'CLOCK0.2 ft. MGO - General Observation - CONNECTION AT THE MH 12 O'CLOCK1.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish1.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock, , within 8 inches of joint: YES90.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"129.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"132 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"168.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"207.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"247.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"287 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"326.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"361.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start365.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"381.4 ft. MWM - Water Mark, 30 %of cross sectional area381.4 ft. AMH - Downstream Manhole, Survey Begins - 05 1651381.4 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (3)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    19.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"

    249.4 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"

  • Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock,  , within 8 inches of joint: YES

    379.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock, , within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
249.4TB
381.4AMH05 1652
55TF
290.9TFC
212.7TFC
379.6CM
0MWM
15.6TFC
381.2MGOCONNECTION AT THE MH 3 O'CLOCK
173.6TF
379.6DAGS
19.6CM
134.1TF
251.6TFC
0AMH05 1651
94.4TF
381.2MGOCONNECTION AT THE MH 12 O'CLOCK
0MWL

Properties (4)

additional_info
SC300398
custom_field_two
3
customer
LACSD
datetime
2016-06-16T02:46:18-07:00